Chosen Solution

Hi, I have error F:06 on the Bosch heat pump dryer WTW87565AU. Does anyone have the service manual for it? I have service manual for the non heat pump version WTV76100US which is very similar, but the error seems to be for the air circuit which is different in this model. There doesn’t seem to be a thermostat for starters, but a temperature probe connected to the compressor. I’m not sure what to check to resolve the error code.

An update that I have found the manuals on another site, Google for these files: f40626bd-3fc9-4e36-b68b-0abc267aea48_wtw86561gb_Tech_Sheet.pdf 1b4b8547-be8d-485d-9de3-98dffec1745c_WTW86561GB_Service_Manual.pdf F:06 is “Fault in heating circuit”, and could be caused by “Over temperature detection of compressor activated”, and the suggestion is to “Check air routes, compressor function and compressor control; replace damaged parts”.

The F6 E2 error code indicates a communication error between the control boards. Often times this is caused by a connection issue rather than a part failure. There are screws on the rear of the top panel that secure the top on. Once removed, the top will slide back and come off to be set aside. Once the top is off, you will have access to the machine controls. WITH THE MACHINE UNPLUGGED, remove each connector, one at a time, and replace into the control. This will rectify any connection issue if there is one. Plug the machine back in and see if the code returns.